12/11/2023 0 Comments Temperature of shelf cloud![]() As may be expected, we have seen a direct correlation between the WAT and the likelihood of operational issues arising from waxing/sludging of the fuel.Thursday afternoon the KMVT Local 11 Weather department received several photos of dark, scary arc shaped cloud that moved across southern Idaho. “VPS has now measured the WAT/cloud point of thousands of VLSFO samples. The method also enables the measurement of WDT which is the temperature at which the last wax solids are melted back into liquid when the oil is heated,” he notes. “This bespoke VPS method allows the WAT/cloud point of VLSFOs to be measured. The method was validated by correlating with current methodology used for distillates, while its repeatability has been confirmed across the range of 10☌ to 65☌. The output was a White Paper (available from the VPS website) outlining an automatic test method for WAT which is the cloud point of VLSFOs. VPS graph showing range of WAT/Cloud Point of VLSFOs during 2020Ī bespoke VPS method to measure WAT/Cloud Point of VLSFOsįortunately, VPS has already conducted a significant amount of research to develop a reliable method for the measurement of cloud point of VLSFOs during Q2/Q3 2019, shared Dr Cooper. “The VPS recommendation is to measure WAT to be absolutely sure of the cloud point and to proactively maintain the fuel condition for efficient storage and handling of the fuel,” suggests Dr Cooper. ![]() This is because measurement of pour point is an unreliable indicator of WAT/cloud point. The development could also mean a shipowner receiving VLSFO with a very low pour point with a high WAT (for example >PP + 20 0C or more) and having his bunkers turn into wax/sludge if following the advisory of CIMAC to store marine fuel at 10☌ above the pour point. Though the occurrence of extremely high WAT measurements has significantly decreased over 2020, attention needs to be given towards an ongoing development where VPS detected an increase in the number of VLSFOs with very low pour points over the past few months. For this reason, the CIMAC recommendation is to keep the fuel at 10☌ above the pour point,” he says. “Current test methods to measure cloud point can only be applied to petroleum products that are transparent in layers of 40mm in thickness. However, the measurement of the WAT and WDT of VLSFOs have always been a challenge as the product, typically a blend of 80% heavy fuel oil (HFO) and 20% marine gas oil (MGO), is not transparent, according to Dr Cooper. Suggest carrying out an exact flashpoint test to make sure that the fuel is not being heated above the flashpoint.Recommendation – Controlled use of additives in some cases can improve the situation just enough to use the remaining fuel.This causes a problem with sludge formation in the storage tank and transfer pipeline, and results in filters clogging with wax, together with serious handling and transfer issues. Characteristics – The product’s separation temperatures may be lower than WAT and for that reason the vessel cannot at any time heat the fuel above WAT. ![]() VLSFOs with low viscosity (40☌ and WDT>75☌)
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |